Miernik mocy optycznej 6 OKIEN, -50~+27dBm BASIC-100098
add
  • Miernik mocy optycznej 6 OKIEN, -50~+27dBm BASIC-100098
navigate_before navigate_next

Optical power meter 6 WINDOWS, -50~+27dBm BASIC

Price: 416.67 zł tax excl.
zł512.50 tax incl.
Out of stock - Delivery to warehouse: 5-7 days

The OPM-15 series of power meters , combined with the SLS from shinewaytech , can meet the requirements of the general fiber identification test, attenuation / loss measurement, continuity verification and transmission quality assessment in SM and MM fibers in the LAN / WAN / CATV infrastructure.

OPM-15 are ideal for both laboratory and field applications, offering high quality, high stability and competitively low costs.



We offer a two-year warranty on this product


Features:
  • Microprocessor and linear amplifier ensure long-term accuracy,
  • Short reaction time,
  • It does not overheat
  • Interchangeable connectors: FC / SC / ST,
  • Two ways to power: 9V alkaline battery and AC adapter,
  • Pocket size, light weight, shock, dust and moisture resistant,
  • Energy saving: auto-off configuration,
  • MOD tones detection,
  • Display units: dB / dBm / mW / µW / W,
  • CE, FCC certificates.



SPECIFICATION
Technical parameters
Model OPM-15B
Calibrated wavelength [nm] (1) 850, 1300, 1310, 1490, 1550, 1625
Power range [dBm] (2) -50 to +27
Application SM / MM fibers
Detector type InGaAs
Accuracy ± 5% ± 0.1nW (± 0.5dB@850)
Resolution [dB] 0.01
Identification of the MOD [Hz] 270, 1000, 2000
Displayed unit W / µW / dB / dBm (REF)
Connector (3) FC (interchangeable with SC, ST)
General parameters
Dimensions (width x length x height) [mm] 75 x 25 x 145 (2.9 x 1 x 5.7 inch)
Weight [g] 300 (0.66 lbs)
Power 9V alkaline battery (450mAh)
AC 9V adapter (optional)
Battery operation time [h] ? 40
Energy saving Automatic shutdown after 5 minutes of inactivity
Working conditions Ambient temperature: -20 to 50 [° C]
Relative humidity: 0 to 95 [%] (no condensation)
The storage conditions Ambient temperature: -40 to 70 [° C]
Relative humidity: 0 to 95 [%] (no condensation)
Comments:
1. Other wavelengths and power ranges are open for adjustment.
2. For the 850nm model A, the lower limit of the measured range is -60dBm (model A) / -50dBm (model B).
3. OPM models with a Ø1000µm detector are available with FC / SC / ST / DIN / E2000 / LC / Universal 1.25mm / Universal 2.5mm connectors.